top of page

Panasonic Aircon Error Code Guide (2025): Complete Troubleshooting for Singapore Homes

  • Writer: 338 Aircon
    338 Aircon
  • 2 days ago
  • 5 min read
panasonic aircon error code

Panasonic air conditioners are among the most widely used cooling systems in Singapore, prized for their efficiency, durability, and user-friendly features.


But like any advanced air conditioning system, they occasionally display an error code that signals a specific malfunction.


For many homeowners, seeing unfamiliar error messages on the remote control can be confusing and stressful, especially during the hot and humid months when cooling is most needed.


This detailed guide covers everything you need to understand about Panasonic aircon error codes.

You’ll learn how to identify the most common codes, understand their causes, follow troubleshooting steps, and decide when it’s time to call a professional.


Quick Takeaways


  • Panasonic aircon error codes act as a diagnostic system for common malfunctions.

  • Frequent issues include sensor abnormality, refrigerant problems, and fan motor errors.

  • Simple troubleshooting includes cleaning air filters, resetting via the remote control, and checking the fuse box.

  • Persistent errors like f93 compressor or power module failures require professional servicing.

  • Regular maintenance prevents costly malfunctions and extends the lifespan of your Panasonic air conditioner.


What Are Panasonic Aircon Error Codes?


Every Panasonic air conditioner comes with a built-in diagnostic function designed to simplify maintenance and repairs.


Instead of guessing why the cooling is weak or why the unit won’t turn on, the system displays specific aircon error codes.


These codes are essentially self-diagnostic signals. They detect malfunctions within the indoor and outdoor units, covering issues such as a faulty fan motor, clogged air filters, refrigerant levels, or sensor abnormalities.


By interpreting these codes, homeowners can determine whether a quick reset will be effective or if expert intervention is necessary.


The brand code design ensures consistency across Panasonic air conditioners, though newer models may add more detailed notifications.


Panasonic Aircon Error Code List & Meanings


Below is a comprehensive table of common Panasonic aircon error codes, their meanings, likely causes, and suggested solutions.

Error Code

Meaning

Common Causes

DIY Fixes

When to Call a Technician

H11

Communication error between indoor and outdoor units

Wiring or PCB issues

Reset power

If error persists

H12 indoor

Indoor unit capacity mismatch

Incorrect unit installation

Verify model

Professional reconfiguration

H14

Room temperature sensor error

Faulty temperature sensor

Reset system

Replace sensor

H15

Compressor temperature sensor abnormality

Overheating

Clean filters, check ventilation

Compressor replacement

H16 outdoor

Outdoor power error

Outdoor unit overload

Reset breaker

Check outdoor unit PCB

H17 / F17 indoor

Indoor fan motor failure

Faulty motor or board

Clean fan blades

Replace fan motor

H18 / F18 dry

Tube temperature sensor

Sensor misread

Reset system

Replace sensor

H19

Indoor heat exchanger temperature sensor abnormality

Faulty sensor or dirty coil

Clean coil

Sensor replacement

H23

Outdoor heat exchanger temperature sensor abnormality

Sensor malfunction

Inspect outdoor coil

Replace sensor

H27

Float switch operation abnormality

Clogged drain line

Clear drain line

Replace float switch

H32 outdoor

Outdoor fan motor error

Cooling fan failure

Inspect blades

Replace motor

H33

Gas sensor abnormality

Refrigerant detection issue

Reset power

Replace gas sensor

H38

Misconnection abnormality

Wrong wiring between units

Verify wiring

Reconfigure wiring

H41

Air temperature sensor abnormality

Faulty sensor

Reset system

Sensor replacement

H44

Ion device abnormality

Ionization unit malfunction

Reset system

Replace ion unit

H62

Compressor discharge temperature abnormality

Overheated compressor

Clean condenser coils

Technician service

H64

Outdoor heat exchanger freeze

Operating unit freeze protection

Low refrigerant levels

Recharge refrigerant

F90

Power module fault

Power module overheating

Reset power

Replace power module

F91

Refrigerant pressure sensor abnormality

Low or high refrigerant levels

Inspect refrigerant

Gas top-up required

F93 compressor

Compressor control board abnormality

Compressor PCB issues

Reset breaker

Replace board

F95 outdoor

Outdoor pressure protection error

Pressure sensor fault

Reset breaker

Replace pressure sensor

U01

Remote control communication fault

Weak signal or dead batteries

Replace batteries

Replace remote control

U02

Transformer abnormality

Electrical fault

Reset breaker

Replace transformer

U03

Write error on control board

Board data corruption

Reset power

Replace control board


This error messages section covers the most common malfunctions that appear across different Panasonic models.


If your specific error code is not listed here, consult the user manual or contact a licensed service provider in Singapore.


Step-by-Step Troubleshooting Guide


When your Panasonic aircon shows error messages, try these simple troubleshooting steps before calling for service:


  1. Check Power Supply: Inspect the fuse box or circuit breaker. A simple reset can clear minor malfunctions.

  2. Inspect Air Filters: Dirty filters are one of the most common causes of cooling issues. Remove, wash, and reinstall.

  3. Reset the System: Use the check button on the remote control or turn off the unit from the breaker for 2–3 minutes before restarting.

  4. Look for Drainage Problems: If the float switch operation displays an abnormality error, inspect the drain lines for clogs.

  5. Temperature Sensor Check: If a temperature sensor error shows, reset the AC and monitor whether the problem recurs.

  6. Cooling Fan Inspection: Ensure the cooling fan in the outdoor unit is working properly.

  7. Refrigerant Levels: Weak cooling or pressure protection errors may indicate low refrigerant levels.


If the issue persists after these steps, it’s best to contact a qualified Panasonic aircon service Singapore technician.


When to Call a Professional


While some minor errors can be cleared with simple troubleshooting, others require professional expertise. You should always call a technician if:


  • Error codes reappear after resetting the unit.

  • There’s a persistent compressor discharge temperature abnormality.

  • The system shows repeated power error notifications.

  • You detect refrigerant leaks or gas sensor abnormality alerts.

  • There are board failures, such as a control board abnormality or a write error.


Professional servicing ensures safety, prevents costly damage, and restores full efficiency.


Preventing Panasonic Aircon Errors


Many aircon errors can be prevented through proactive maintenance. Here’s how:


  • Clean Filters Regularly: Wash or replace filters every 2–4 weeks.

  • Inspect Coils and Drain Lines: Ensure airflow is unobstructed and drainage is clear.

  • Schedule Annual Servicing: Professional checks detect pressure sensor problems, module malfunctions, and transformer abnormality before they escalate.

  • Avoid DIY Repairs: Unless it’s a simple reset, always rely on qualified aircon technicians.


Why Professional Servicing Matters in Singapore


In Singapore’s hot and humid environment, the air conditioning system works almost year-round. Small malfunctions like sensor error or fan motor failures can snowball into larger, costly breakdowns if ignored.


Professional AC servicing helps maintain energy efficiency, ensures refrigerant levels are correct, and keeps your home comfortable and well-maintained.


Companies like 338 Aircon specialize in repairing Panasonic air conditioners, offering diagnostics, repair, and full system maintenance tailored to local needs.


FAQ: Panasonic Aircon Error Codes


1. How do I reset my Panasonic aircon?


Turn off the unit at the circuit breaker, wait for 2–3 minutes, and restart. Alternatively, press the check button on the remote control to clear temporary errors.


2. Why does my Panasonic AC show error code H11?


This indicates a communication error between indoor and outdoor units. If the error persists after a reset, it may involve wiring or PCB faults that need a technician.


3. Can I fix Panasonic aircon error codes myself?


Minor malfunctions like clogged air filters or drain issues can be resolved at home. However, sensor error, control board abnormality, or compressor issues require professional servicing.


4. How much does Panasonic aircon repair cost in Singapore?


Repairs vary by problem. Simple fixes like drain cleaning may cost $80–$120, while compressor replacements or control board repairs may exceed $300.


5. What’s the most common Panasonic error code?


One of the most frequent is H14, which indicates a room temperature sensor error. It often requires sensor replacement if cleaning or resetting doesn’t help.


Final Thoughts


Understanding Panasonic aircon error codes empowers homeowners to troubleshoot basic issues and know when professional help is necessary.


While some errors are simple—like cleaning air filters or resetting the unit—others, such as compressor discharge temperature errors, pressure protection failures, or control board malfunctions, demand expert attention.


If your Panasonic air conditioner shows persistent error messages, don’t wait until the system breaks down completely.


Contact a trusted Singapore service provider like 338 Aircon for prompt and reliable troubleshooting, ensuring your cooling system runs efficiently throughout the year.

Comments


Aircon servicing & installation

About Us

338 Aircon provides the most affordable aircon services in Singapore. Our professional technicians specialise in installations, repairs, and maintenance for residential and commercial clients. Committed to customer satisfaction and competitive prices, we are your trusted partner for all your aircon needs.

15

Years' Experience

4058

5-Star
Aircon servicing & installation
Rating

165,326

Aircon Units Serviced
bottom of page